Prepare the Inhaler: Remove the cap from the inhaler and shake it as per the manufacturer's instructions. Assemble the Chamber: Insert the inhaler into the backpiece of the AeroChamber Plus® Flow-Vu® chamber. Apply the Mask: Place the anatomically shaped small mask over the infant's nose and mouth, ensuring a secure seal. Administer Medication: Exhale: Have the infant exhale gently. Activate Inhaler: Press the inhaler once at the beginning of a slow inhalation. Inhalation: Allow the infant to breathe in and out through the chamber for 5–6 breaths. Post-Use: Remove the mask and clean the chamber as per the cleaning instructions below
Mask Size: Small (0–18 months) Material: Anti-static polymer Dishwasher Safe: Yes, top rack only at temperatures up to 158°F (70°C) BPA-Free: Yes Latex-Free: Yes Phthalate-Free: Yes PVC-Free: Yes Replacement Interval: Every 12 months or as needed
Temperature Range: Store and operate the chamber within 5°C to 40°C (41°F to 104°F) at 15% to 95% relative humidity. Cleaning: Clean the chamber weekly by soaking it in a mild solution of liquid dish detergent and lukewarm water for 15 minutes. Alternatively, place it in the top rack of a dishwasher on a normal or light cycle. Do not use heated drying. Replacement: Replace the chamber every 12 months or if any components are damaged or no longer fit properly. Supervision: Always supervise the infant during medication administration.
Enhanced Medication Delivery: Improves the deposition of inhaled medications into the lungs, reducing side effects associated with oral or throat deposition. Ease of Use: Simplifies the inhalation process for infants, ensuring more effective treatment. Comfortable Fit: The anatomically shaped mask contours gently to the infant's face, providing a secure seal with minimal effort. Visual Feedback: The Flow-Vu® inhalation indicator moves with the infant's breath, helping caregivers ensure correct inhalation technique.
Flow-Vu® Inhalation Indicator: Provides visual assurance that the infant is inhaling correctly, aiding caregivers in proper medication delivery. EZ Flow Exhalation Valve: Directs exhaled air away from the chamber, preventing medication from being affected by exhaled air. Compatibility: Compatible with most commonly prescribed metered-dose inhalers.
The AeroChamber Plus® Flow-Vu® chamber is constructed from anti-static materials to minimize medication loss due to static cling. It is free from BPA, PVC, phthalates, and latex, ensuring safety for infants.